Home > Candidates > Cristian Rusu
Cristian Rusu

BUCHAREST BUCHAREST, Romania

Phone: xxx-xxx-xxxx

Email: xxx@xxxx.xxx



  • Looking For: Field Engineer Mechanical, Generator Specialist

  • Occupation: Architecture and Engineering

  • Degree: Bachelor's Degree

  • Career Level: Experienced

  • Languages: English(advanced), French (advanced), Italian & Spanish (beginner)

Career Information:

Sign up to view Cristian Rusu's full profile.

Highlights:

Skills:power plant skilled engineer, Technical Field Advisor


Experiences:

TFA Generator Specialist 01/18/2018 - current
FieldCore Service Solutions, BUCHAREST, BUCHAREST Romania
Industry: Power
Able to perform Generator disassembly and mechanical reassembly jobs, and to supervise removal and installation of generator field in the stator; Execute End Winding Upgrade on Connection Rings; Remove and install Retaining Rings on the generator field; Perform Hit Skid and FAB Skid Tests, and AC Hipot Test on the stator; o Inspect and perform minor dusting repairs on generator end winding and connection rings; Perform partial or complete re-wedge of generator stator core; Perform low voltage and high voltage electrical tests on the field, stator and excitation system.
Electrical tests on the Stator: • Insulation resistance test (IR) by using Megger tester • Polarization index measurement (PI) • Armature winding resistance measurement • Perform EL CID test (Electric Core Imperfection Detection Test) • Perform Core Ring Test • RTD Element Resistance and insulation resistance • DC Leakage Test & DC Hi-Pot Test Electrical tests on the Field: • Insulation resistance test (IR) and Polarization Index (PI) • Field winding resistance measurement by using Digital Low Resistance Ohmmeter (DLRO) • AC impedance test by using a Variac • Recurrent Surge Oscillography Test (RSO) • Partial Discharge & Tan Delta Tests--
Maintenance Engineer 10/01/2016 - 10/01/2017
SKH – SNC Lavalin Constructeurs International Inc., Hadjret En Nouss, Tipaza Algeria
Industry: Power
Technical Advisor – Technical & Maintenance Departments
Quality Management and Control of the Tasks Performed During MI, CI and HGP Inspections of Single-Shaft GT-GEN-ST + Plant Maintenance Program Improvements Equipment: 9FB Gas Turbine + 450H type Generator hydrogen cooled + A15 Steam Turbine--
Deputy Technical Director 10/01/2015 - 10/01/2016
SKH – SNC Lavalin Constructeurs International Inc., Hadjret En Nouss, Tipaza Algeria
Industry: Power
Site: HADJRET EN NOUSS - ALGERIA Position: Deputy Technical Director
Quality Management and Control of the Tasks Performed During MI, CI and HGP Inspections of Single-Shaft GT-GEN-ST Plant Maintenance Program Improvements Single Shaft Unit: 9FB Gas Turbine + 450H type Generator hydrogen cooled + A15 Steam Turbine--
TFA Generator Specialist & GT Mechanical 09/17/2007 - 10/01/2015
General Electric, BUCHAREST, BUCHAREST Romania
Industry: Power
GENERATOR SPECIALIST/FIELD ENGINEER GAS TURBINE/TECHNICAL ADVISOR
Ensure the correct GE installation, pre-commissioning and commissioning practices are followed throughout the project, filling and/or requesting sub-contractors to fill the relevant check lists o Able to supervise qualified manpower to perform Combustion Inspections, Hot Gas Path Inspections and Major Inspections for GE Gas Turbines frames 5C, 6FA, 6B, 7FA/9FA, 9E o Execute boroscope inspections (BI) with portable equipment and interpret the results for generators, gas turbines, compressors and combustion systems--

Education:

Polytechnical University of Bucharest 06/1989 - 07/1994
Bucharest, , Romania
Degree: Bachelor's Degree
Major:Power Plant Engineer
Graduated The Bucharest Polytechnic University(1989-1994) - Faculty:Energetics / Power Plants


Download Resume(Available to Employers Only):

Login to view resume: Cristian Rusu - Resume



More About Cristian Rusu
Please sign in or sign up an employer to view Cristian Rusu's personal information.

  • Phone: xxx-xxx-xxxx
  • Email:xxx@xxxx.xxx
  • Visa: -
  • Work Authorization: -
  • Expected Salary: -
  • Intests & Hobbies: -